ACTentry A10 Operating and Installation Instructions
0 Toggled
1 Timed
2 Timed
3 Timed Timed
4 Timed
5 Timed Timed
6 Timed Timed
7 Timed Timed Timed
ACTentry A10 Programming
Press the button followed by the programming code (initially 9999). The yellow LED will ash while
in programming mode. To exit the programming mode press button
. Exit from programming mode
occurs automatically if no key is activated for 30 seconds.
Changing Codes:
(From programming mode)
Enter 0 (Change codes)
0-9,
(user number 0-9, = programming code)
000000-999999 (4 or6digit code 000000 deletes user)
Default user codes: Programming = 9999(99), User1=1234(56), All others inactive.
Setting switched output combinations:
(From programming mode)
Enter 1 (Set Outputs)
0-9 (User number 0-9)
0-7 (Output function code)
Output Function Code Door Output Door 2/Output 2 Output 3
Default function code is1(Relay Timed) for all users. When the door is toggled open, this will be
For example, to set user 1 to toggle the door open/locked:
Enter 1(set outputs), followed by 1(user1), followed by 0(Toggled). (e.g -9999-1-1-0- )
To set user 2 to open Door 2:
Enter 1(set outputs), followed by 2(user2), followed by 2 (Door 2 timed) (e.g. -9999-1-2-2- )
Setting timers:
(From programming mode)
Enter 2 (Set Timers
0-4 (Timer number) {Buzzer sounds indicating timing… wait required period}
(Stop timing) {Buzzer stops timer set}